Construction applications standards q a.
Bus drop cable nec.
Ampacities are from table 310.
364 8 in the busway article.
Royal bus drop view pdf.
Stranded bare copper per astm b 8 2.
Bus drop cable and tray cable are service cords that connect a power supply to a machine or device.
For use as drop cable from overhead bus duct to floor machines.
Pcv standrad color gray other colors available upon request applications and features.
At least one leading national authority says you re only allowed to make such extensions from busways.
Easily disconnected and connected when machines are moved.
Spec 70168 bus drop cable industrial grade construction.
Bus drop cable and tray cable are service cords that connect a power supply to a machine or device.
The 1999 nec now refers only to sec.
Acic pcs duo power control signal cable csa view pdf.
Bus drop cable is typically used as a branch connection from a ceiling cable while tray cable is primarily used for wiring.
Installed quickly without use of conduit for fixed or temporary power.
Ampacities of insulated conductors from nec table nec310 15 b 16 not more than three conductors in raceway or cable or earth directly buried based on ambient temperature of 30 c 86 f print this page.
Pvc colors black white red 3.
The cable is covered with a gray pvc jacket.
Aluminum conductors copper clad conductors.
60 c 140 f 75 c 167 f 90 c 194 f 60 c 140 f.
Bare stranded copper.
This cable consists of three bare copper insulated conductors and three bare copper 4.
Allied wire and cable s bus drop cable is designed for both indoor and outdoor use in wet or dry locations for the connection of portable or stationary equipment to facilitate their interchange our particular bus drop cable is constructed with a polyvinylchloride jacket and depending on the awg has a temperature rating of either 60 ºc or 75ºc and a voltage rating of 600 volts.
Bus drop cable is typically used as a branch connection from a ceiling cable while tray cable is primarily used for wiring.
Bus drop cable pvc insulation pvc jacket applications.
Resistant to oil grease acids cutting fluids and mechanical abuse.
This comes up in locations where you d like to attach the drop to the wall from a wireway run overhead at a central point.
The 1996 nec allowed one building surface attachment.
Nec 364 8 as branch wiring from busways.
They have two or more insulated conductors and a protective jacket that resists abrasion water sunlight and lubricants.
Bus drop cable is made for use in indoor or outdoor applications for connection of stationary or portable equipment to facilitate relocation of equipment.
Bus drop cable 60 c 600 volt ul.